Connecting To Compressed Air System; 1) Connecting Air Supply; 2) Setting Operating Pressure; Electrical Connection - BLUM MINIPRESS P Operator's Manual

Boring and insertion machine
Hide thumbs Also See for MINIPRESS P:
Table of Contents

Advertisement

80
60
100
40
120
140
20
PSI
0
2.9
2 - Machine setup
2.11

2.2 - Connecting to compressed air system

2.2.1) Connecting air supply

ATTENTION:
During the following procedure, the boring unit
makes an upward motion
2.12
• Connect the air supply to the system vent valve
This valve is used to vent air pressure from the air control system. Note that the air
7.1
pressure remains in the cylinder when the system vent valve
2.8
tion (see section 7.4 for cylinder venting instructions).
• Slide 3/8" rubber ID hose onto the barbed connector provided
• Optional adapter for 3/8" NPT male threads is available
• Open system vent valve
• This system vent valve is used to vent the air pressure from the air control system
ATTENTION:
A quick disconnect must be inserted in the air line supply a max. 6 feet
(1.8 meters) from the machine.

2.2.2) Setting operating pressure

• Set operating pressure set 90 psi using pressure adjusting knob
(Pmin= 80 psi)
(Pmax= 100 psi)
ATTENTION:
Do not set the regulated air pressure above 100 psi. Higher pressure
may result in equipment damage or personal injury or both.

2.3 - Electrical connection

2.3.1) Electrical connection
ATTENTION:
The electrical connection must be performed by a qualified electrician!
ATTENTION:
The machine is designed for the voltage printed on the label of the con-
nection cable. Incorrect voltage may result in equipment damage
or personal injury or both.
• Set power switch
• Mount a plug conforming to DIN, VDE, IEC or UL requirements, or hardwire machine
directly to the supply circuit.
• Provide for circuit breaker of 15 A (see Chapter 10 - Diagrams).

2.3.2) Checking motor rotation

ATTENTION:
During the following procedure, keep your hands away from the work
area of the machine
• Set power switch
• Briefly press (3.2) drill/press stroke switch
3.1
• The motor fan
3.2
(3.1)
to OFF
to ON
(3.1)
(2.9)
must turn in the direction of the arrow
11
(4.23)
(2.12)
on the air filter assembly
(2.12)
is in the vent posi-
(2.11)
BA-106/1EA M53.10XX
(7.1)

Hide quick links: