Trigger Overlap
In the GO-5000M-PGE-UV, the trigger overlap function is fixed to Read Out.
Read Out: The trigger pulse can be accepted during the sensor readout.

Normal continuous operation

This is used for applications which do not require triggering.
Primary settings to use this mode
Minimum frame interval

Timed mode

This mode allows a single image frame to be captured with a preset exposure time by using the
external trigger. Additional settings determine if the trigger pulse can be accepted during the
exposure period.
Primary settings to use this mode
Exposure Mode: Timed
Trigger Mode: ON
Trigger Source: Opt IN (6p connector)
Trigger Option: OFF
Optical Filter Selector: 10μs
Minimum frame interval