JAI GO-5000M-PGE-UV User Manual page 45

Cmos digital progressive scan monochrome uv camera
Hide thumbs Also See for GO-5000M-PGE-UV:
Table of Contents

Advertisement

GO-5000M-PGE-UV
Minimum interval of the trigger
Readout mode
Trigger Sequence mode basic timing
In this mode, as each trigger input is received, the image data associated with the next
index within the preset sequence is output.
In the trigger sequence mode, it is not possible to input the trigger while the current index is
executing.
The sequence index table always starts at Index 1 and changes to next index which is preset in the
next index setting after the current index is completed.
— 45 —