IQ7PLUS-72-E-ACM-INT/IQ7PLUS-72-ACM-INT Microinverter Parameters
Topic
Dimensions not including mounting bracket
(approximate)
Connector type
Weight
Environmental Category / UV Exposure rating
Cooling
Relative humidity range
Approved for wet locations
Pollution Degree
Maximum altitude
Communication
Compliance
Grounding
Monitoring
Integrated DC disconnect
Integrated AC disconnect
33
© 2021 Enphase Energy Inc. All rights reserved.
IQ Microinverter for ACM Applications
Unit
Min
219 mm x 191 mm x 37.9 mm
MC-4 or Amphenol UTX
1.5 kg (3 lbs.)
IP67 Outdoor
Natural convection - no fans
4% to 100% condensing
Yes
PD3
2000 meter (6561 feet)
Power line
AS 4777.2, RCM, IEC/EN 61000-6-3, IEC/EN 62109-
1, IEC/EN 62109-2
The DC circuit meets the requirements for ungrounded
PV arrays in NEC. Ground fault protection (GFP) is
integrated into the class II double insulated
microinverter.
Enlighten Manager and MyEnlighten monitoring
options require an Enphase IQ Envoy
The DC connector has been evaluated and approved
for use as the load-break disconnect.
The AC connector has been evaluated and approved
for use as the load-break disconnect required.