Specifications; Iq7-60-Acm-Int Microinverter Specifications - enphase IQ 7 Installation And Operation Manual

Microinverters for acm applications
Table of Contents

Advertisement

Specifications

See specifications in the following tables for:
IQ7-60-ACM-INT
IQ7PLUS-72-ACM-INT, IQ7PLUS-72-E-ACM-INT
IQ7X-96-ACM-INT
IQ7A-72-E-ACM-INT

IQ7-60-ACM-INT Microinverter Specifications

Topic
Commonly used module pairings1
Peak Power Tracking Voltage
Operating voltage range
Maximum input DC voltage
Minimum / Maximum start voltage
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum continuous AC output power (-40C to
+65C)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
230 VAC (single phase)
Maximum continuous output current
230 VAC (single phase)
Nominal frequency
Extended frequency range
Maximum AC output over current protection device
1
Nominal Voltage Range can be extended if required by the utility.
30
Enphase IQ7-60-ACM-INT Microinverter Parameters
DC Parameters
AC Parameters
1
© 2021 Enphase Energy Inc. All rights reserved.
IQ Microinverter for ACM Applications
Unit
Min
V
27
V
16
V
V
22
A
A
1x1 ungrounded array; No additional DC side protection
required; AC side protection requires max 20 A per
branch circuit
VA
VA
Vrms
184
A
Hz
Hz
45
A
Typical
Max
235 W – 350+ W
37
48
48
48
15
II
0
240
250
0.8 leading
0.8 lagging
276
1.04
50
55
20
January 06, 2021