enphase IQ 7 Installation And Operation Manual page 36

Microinverters for acm applications
Table of Contents

Advertisement

Topic
Maximum DC input short circuit current (module Isc)
Overvoltage class DC port
DC Port backfeed under single fault
PV array configuration
Maximum Continuous AC output Power (-40 to +65C)
Peak output power
Power factor (adjustable)
Nominal AC output voltage range
230 VAC (single phase)
Maximum continuous output current
230 VAC (single phase)
Nominal frequency
Extended frequency range
Maximum AC output over current protection device
Overvoltage class AC port
AC port backfeed under single fault
Power factor at rated power
Maximum microinverters per 20 amp (max) AC branch
circuit - 230 VAC (single phase)
EN 50530 (EU) weighted efficiency
230 VAC (single phase)
Static MPPT efficiency (weighted, ref EN 50530)
Total harmonic distortion
Ambient temperature range
Night tare loss
Storage temperature range
Dimensions not including mounting bracket
(approximate)
Connector type
Weight
Environmental Category / UV Exposure rating
Cooling
36
IQ7A-72-E-ACM-INT Microinverter Parameters
AC Parameters
Miscellaneous Parameters
Features and Specifications
© 2021 Enphase Energy Inc. All rights reserved.
IQ Microinverter for ACM Applications
Unit
Min
A
A
1 x 1 ungrounded array; No additional DC side
protection required; AC side protection requires max
20 A (single-phase) / 25 A (multiphase) per branch
circuit
VA
VA
Vrms
211
A
Hz
Hz
45
A
20 A (single-phase) / 25 A
(multiphase) per branch circuit
A
39 (multiphase, requires 25 A
%
96.5
%
99.5
%
C
-40
mW
C
-40
219 mm x 191 mm x 37.9 mm
Model IQ7A-72-E-ACM-INT: EN-4 Bulkhead
1.5 kg (3 lbs.)
IP67 Outdoor
Natural convection - no fans
Typical
Max
15
II
0
366
349
0.8 leading
0.8 lagging
240
264
1.52
50
55
III
0
1.0
11 (single-phase)
OCPD)
5
+65
50
+85
January 06, 2021