Communication Protocol Baud Rate Setting (Sw2); Baud-Rate Setting; Tud; Tmd - Advantech AMAX-1220 Series User Manual

Table of Contents

Advertisement

2.5
Communication Protocol Baud Rate Setting
(SW2)
Swtich
Label
1
SPD1
2
SPD0
3

TUD

4

TMD

5
BRK
6

EMG

2.5.1

Baud-Rate Setting

SPD1
OFF
OFF
ON
ON
2.5.2
TUD
This terminal is used to set output conditions when the watchdog timer times out.
OFF
ON
2.5.3
TMD
When the interval between data packets sent from a master card (ex. PCI-1202U) is longer
than the specified interval, the watchdog timer times out.
20 Mbps
OFF
20 ms
ON
5 ms
2.5.4
EMG
This terminal is used to set input conditions when the emergency stops occurrence.
OFF
ON
Description
Baud-Rate Setting
Time-Out Status Latch
Specify watchdog timer time
*For internal use only, please keep in OFF
Emergency stop control
SPD0
OFF
ON
OFF
ON
The output keeps its current status.
The output is Reset.
10 Mbps
40 ms
10 ms
High active
Low active.
21
20 MHz
10 MHz
5 MHz
2.5 MHz
5 Mbps
2.5 Mbps
80 ms
160 ms
20 ms
40 ms
AMAX-1220/1240 Series User Manual