4. Make sure the inner element (4) remains in place.
5. Clean inside of air cleaner housing and check that the
sealing surfaces for inner and outer elements are clean.
6. Install new inner and outer air cleaner elements into
housing.
Make sure that both elements seals are
seated against the inside of the air cleaner housing.
7. Reinstall cover (2) and secure cover to air cleaner
housing with the three retaining clips (1).
7 - MAINTENANCE
7-38
4
GNIL14TR00504AA.PNG
5
GNIL14TR00501AA.PNG