System Board; Replacing The System Board - Fujitsu PRIMERGY GX2460 M1 Upgrade And Maintenance Manual

Table of Contents

Advertisement

System board and components
13.3

System board

13.3.1 Replacing the system board

Field Replaceable Unit
(FRU)
Tools: Replacing the system board:
– Phillips PH2 / (+) No. 2 screw driver
– hexagon screw driver 5 mm (for OCP bolts)
– Magnifying glass for inspecting CPU socket springs
(recommended)
Replacing the TPM:
– Bit screw driver
– flat nose pliers
– TPM bit insert
– thin slotted screw driver (2 x 0.4 mm)
(
)
*
For Japan:
– Dedicated TPM screw driver (CWZ8291A)
– TPM module fixing tool (S26361-F3552-L909)
If an OCP module is installed:
– Phillips PH1 / (+) No. 1 screw driver
Note on network settings recovery
I
When replacing the system board, network configuration settings in the
system will be lost and replaced by default values. This applies to all
static IP address and LAN teaming configurations.
Ensure to note down your current network settings before replacing the
system board.
Note on configurations with LRDIMMs
I
After replacing the system board, it is necessary to set the memory
operation mode in the BIOS in the same way as before.
212
(
)
*
Upgrade and Maintenance Manual
Hardware: 50 minutes
Software: 10 minutes
(
)
*