Programmable Bidirectional DC Power Supply 62000D Series
Operating and Programming Manual
When multiple DC power supplies are connected in series or parallel,
only one DC power supply can be the Master and the rest have to be set
to Slave.
For example:
1.
2.
3.
4.

3.2.4.2.5 Parallel Mode Connection

1.
When the parallel communication interface is installed, follow the steps described in previous
section to enter into Serial & Parallel page as Figure 3-55 shows. .
2.
Set on one unit to Master, all others should be set to Slave mode.
3.
When paralleling two units set Master+
4.
After the above settings are made, M/S Control should be enabled to perform parallel
connection control. When the connection is successful, the Master device display as Figure
3-56 (ex.62180D-600) shows while the Slave device displays as Figure 3-57 shows.
3-36
Figure 3-55
If there are 5 sets connected in parallel and 150V/600A is set, the
setting of each set is 150V/120A and the total output will be
150V/600A.
If there are 2 sets connected in series and 1200V/60A is set, the
setting of each set is 600V/60A and the total output will be
1200V/60A.
The total sets for connecting in series are 2; therefore, the
maximum number of Master+
The total sets for connecting in parallel are 10; therefore, the
maximum number of Master+
1
is 1.
9
is 9.
as shown in Figure 3-55.
1