Chroma 62000D Series Operating And Programming Manual page 29

Programmable bidirectiona dc power supply
Table of Contents

Advertisement

System Fault indicator
(O/P)
Safety interlock (I/P)
Remote inhibit (I/P)
Series & Parallel
operation
Auto Sequencing (List
mode)
Number of program
Number of sequence
Dwell time Range
Trig. Source
Auto Sequencing (Step
mode)
Start voltage
End voltage
Run time
Trig. Source
Input Specification
AC input voltage
3phase, 3wire + ground
AC frequency range
Power factor
General Specification
Maximum Remote
Sense Line Drop
12
Compensation
Operating Temperature
Rage
Storage Temperature
Rage
Dimension Size
(HxWxD)mm
Weight (kg)
All specifications are subject to change without prior notice.
Note
Minimum output voltage is <0.5% of rate voltage at zero output setting.
1.
2.
Minimum output current is<0.2% of rate current at zero output setting when
measured with rated load resistance.
3.
For input voltage variation over the AC input voltage range with constant rated
load.
Master / Slave control for Parallel: 10 units
3Φ 200Vac - 220Vac ±
10%
3Φ 380Vac - 480Vac ±
10%
(Output=8kW@200-
220 Vac input,
Output=12kW@380-
480 Vac input)
w/o Neutral
2% of full scale voltage per line(4% total)
133 x 428 x 730 mm / 5.23 x 16.85 x 28.74 inch
32kg / 70.5lbs
TTL: Active Low
Time accuracy: <100ms
TTL: Active Low
10
100
2ms – 15,000s
Manual / Auto / External
0 to Full scale
0 to Full scale
00.001Sec to 100hr
Auto
3Φ 200Vac - 220Vac ± 10%
3Φ 380Vac - 480Vac ± 10%
(Output=12kW@200-220 Vac input,
Output=18kW@380-480 Vac input)
w/o Neutral
47 – 63 Hz
Source
PF>0.97 @220Vac
PF>0.97 @380Vac
PF>0.95 @480Vac
Regn
PF>0.97 @220Vac
PF>0.95 @380Vac
PF>0.92 @480Vac
0  C ~ +40  C
-25  C ~ +70  C
39kg / 86.0lbs
Overview
1-11