HTML Interface
The PBXgateway can be configured using a standard web server over an existing LAN connection. This
feature provides the system administrator complete management capabilities as well as status
information for both WAN and PORT connections.
IMPORTANT:
•
All IP parameters for the PBXgateway must be configured before the web server session can be
established.
•
The PBXgateway must be connected to the LAN via the LAN port.
•
The PBXgateway must be powered up and online (see Power-up procedure on page 20).
Procedure
1. Access the Management Interface (MI) using a Telnet session or via the Console Port.
2. Access the Web Server parameter using the following path:
Configuration->IP->LAN->Web Server
3. Select YES for Enabled. Set the Timeout to 30.
4. Save the settings and Log out of the MI.
5. Open any web browser from your PC. Example: Windows Internet Explorer (version 5.X or higher).
6. At the http:// prompt type in the IP Address of the PBXgateway as shown below.
The HTML pop-up window will appear.
PBXgateway II Quick Installation Guide
Figure 23:
http Prompt
Figure 24:
Managing the Device
56