Upgrading to TPC Software v2.6 or Higher
NEW LAMP SETTINGS: Note that TPC software v2.4d or higher provides new increased current limits
14.
for all lamps:
Model
i
CP2000-
CP2000-
h
Note 1: All current ranges shown here include "over-drive", which is 10% more than the original
lamp rating.
Note 2: Other CP models are compatible with all 4 lamps. 3) "Old" = v2.4c or older. "New" =
v2.4d or higher.
Because of these expanded ranges, previous user-defined Lamp Power settings (such as a Lamp Power
setting saved with a particular channel) will produce less light than in v2.4c or older. Therefore, if you
have upgraded from v2.4c (or older), you must define new Lamp Power values to regain the desired
performance:
Recalibrate Foot Lamberts: Re-do this calibration to provide accurate foot lambert interpolations.
Refer to the projector's User's Manual for instructions.
Redefine Lamp Power Settings: Redefine any Lamp Power settings for use with specific channels.
Refer to the projector's User's Manual for instructions.

Troubleshooting:

If FFFTP fails to download files properly, reconnect the TPCServer (refer back to page 2), and try again.
If FFFTP still fails to download files properly, re-boot the TPC by disconnecting then re-connecting it.
If FFFTP still fails to download files properly, try the WS_FTP or similar program.
Page 8 of 9
CXL/CDXL Lamps
(kW)
CDXL-20
(2.0)
CXL/CDXL-30 (3.0)
CXL/CDXL-45 (4.5)
CXL/CDXL-60 (6.0)
Old Current Range
(amps)
66-88
82-120
112-150
126-170
New Current Range
(amps)
66-98
82-128
112-160
126-180
010-101108-01 Rev. 1 (11/06)