Idle Shut Down Function - Daewoo Novus M2SEF Manual

Table of Contents

Advertisement

https://www.truck-manuals.net/
6) How to Handle the vehicle(for DDC engine)
MTA0041
MTA0042
1-3 HOW TO HANDLE THE VEHICLE

(1) IDLE SHUT DOWN function

1) Engine automatically stops after 5 minutes
passed when engine is idling for reducing
fuel consumption and air pollution
2) Restart engine for driving after engine has
stopped automatically
Caution
1. Limit idling time within 10% (1 hour approximately)
of during initial driving of 15 hours.
2. Unnecessary idling during initial operation could
damage electrical fuel injection system(ECU)
3 minutes of engine warming-up is enough in
winter time.
(2) Cautions for engine abnormalities during driv-
ing
1) Check Engine indicator : indicates engine's
malfunction, power is limited to 70% of total
level automatically.
2) Stop Engine indicator : indicates serious prob-
lems on engine, power is limited to 40% of
total level, Move the truck to safe place within
the time before engine automatically stops
after 30 seconds of indication. Press the
switch within 25 seconds after indicator came
up for extending operation time as much as
30 seconds. (refer to page 45, "Engine di-
agnosis switch")

Advertisement

Table of Contents
loading