10. HYDRAULIC DEVICE OF CAR CARRIER

4
7
6
1
1
1
Operation
Hydraulic pressure is generated by gear pump driven by PTO. Oil with high pressure is then trans-
ferred to the unit of the car carrier and its pressure is maintained below(4) solenoid relief valve preset
pressure (100kg/cm
2
PTO switch while the key is 'ON'.
https://www.truck-manuals.net/
8
9
5
MTF1000
). Operation of solenoid valve is activated by a switch on car-carrier unit with a
MTF1010
5-163 MISCELLANEOUS CONTROLS AND OPTIONS

Circuit diagram

1.

Oil tank

2.
Suction strainer
3.
Gear pump
4.
Solenoid relief valve
5.
Return valve
6.
Stopping valve
7.
Pressure gauge
8.
Oil hose - Socket
9.
Oil hose - Plug
Oil tank
1. Oil capacity : 301 (up to the indication mark of
gauge)
2. Suction strainer : Passing by flow : 501/min(mesh
150)
3. Oil type : ISO VG 32
4. Interval for replacement : Every 1 year after initial
change at 3 months.
(Suction strainer needs to be replaced at the same
time)