3-108 INSPECTION AND MAINTENANCE
4. Remove the old gasket from the valve and dis-
card. Check that only one gasket is used.
5. Coat the new cylinder's threads with clean en-
gine oil.
6. Install the starting fluid cylinder by turning the
cylinder in the direction of the arrow (clockwise),
until the cylinder dirt and moisture seal O-ring
contacts the valve.
Caution
Do not over tighten the cylinder. Overtightening may
damage the valve or the cylinder.
7. Tighten an additional 11/2 turns(540). Retighten
the cylinder clamp.
8. Reset the LCI by passing a magnet over the
designated reset area 3 or 4 times. The lamp
should flash indicating a reset.
Caution
The contents of the cylinder should be allowed to
settle back down before a system is operated. This
takes approximately 15 to 20 minutes. Failure to
allow this settling often causes premature clogging of
the system and necessitates cleaning or replace- ment
of the valves BLOCKOR® metering orifice fil-
ter. This also applies to a system being installed.