9.1 HAND HELD ANALYZER
To Connect the Hand Analyzer
1.
Connect the four pin end of cable supplied with the
analyzer to the four position connector on the plat-
form console and connect the remaining end of the
cable to the analyzer.
2.
Power up the Control System by turning the lower
key to platform position and pulling both emergency
stop buttons on.
Figure 9-1. Hand Held Analyzer Connection
Using the Analyzer
With the machine power on and the analyzer connected
properly, the analyzer will display the following:
HELP:
PRESS ENTER
At this point, using the RIGHT and LEFT arrow keys, you
can move between the top level menu items. To select a
displayed menu item, press ENTER. To cancel a selected
menu item, press ESC; then you will be able to scroll
using the right and left arrow keys to select a different
menu item.
31210090
SECTION 9. JLG CONTROL SYSTEM
– JLG Lift –
SECTION 9 - JLG CONTROL SYSTEM
The top level menus are as follow:
(Also see § 9-2 Analyzer Screen Layout).
HELP:
DIAGNOSTICS
SYSTEM TEST
ACCESS LEVEL 2
PERSONALITIES (See Table 9-3)
MACHINE SETUP (See Table 9-1)
If you press ENTER, at the HELP:PRESS ENTER dis-
plays, and a fault is present during power up, the analyzer
display will scroll the fault across the screen. If there was
no fault detected during power up, the display will read:
- In platform mode,
HELP:(001)
EVERYTHING OK,
- In ground mode,
HELP:(002)
GROUND MODE OK,