DTC
FAULT MESSAGE
9996
MASTER MODULE MEMORY
FAILURE
9997
SLAVE MODULE MEMORY
FAILURE
9998
MASTER MODULE PROTEC-
TION FAILURE
9999
SLAVE MODULE PROTEC-
TION FAILURE
99100
MASTER MODULE FAILURE -
CHECK POWER CIRCUITS OR
MOSFET SHORT CIRCUIT
99101
SLAVE MODULE FAILURE -
CHECK POWER CIRCUITS OR
MOSFET SHORT CIRCUIT
99102
MASTER MODULE WATCH-
DOG RESET
99103
SLAVE MODULE WATCHDOG
RESET
99104
MASTER MODULE WATCH-
DOG2 RESET
99105
SLAVE MODULE WATCH-
DOG2 RESET
99106
MASTER MODULE RAM FAIL-
URE
99107
SLAVE MODULE RAM FAIL-
URE
99108
MASTER MODULE - INTER-
NAL ERROR
99109
SLAVE MODULE - INTERNAL
ERROR
99110
MASTER MODULE - INTER-
NAL ERROR
99111
SLAVE MODULE - INTERNAL
ERROR
31210090
DESCRIPTION
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
A short circuit on the power outputs of the
Master Module (right controller) has been
detected.
A short circuit on the power outputs of the
Slave Module (left controller) has been
detected.
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
There is an internal error in the Master
Module (right controller).
There is an internal error in the Slave Mod-
ule (left controller).
– JLG Lift –
SECTION 10 - DIAGNOSTIC TROUBLE CODES
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Replace the Master controller.
• Replace the Slave controller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Master con-
troller.
• Cycle power to clear the fault.
• If the fault is not cleared : Replace the Slave control-
ler.
CHECK
10-21