DTC
FAULT MESSAGE
4418
MASTER MODULE VOLTAGE
OUT OF RANGE
4419
SLAVE MODULE VOLTAGE
OUT OF RANGE
4420
(MASTER MODULE BATTERY
VOLTAGE DEEPLY DIS-
CHARGED)
BATTERY DEEPLY DIS-
CHARGED

4-6 Transmission and Drive System

DTC
FAULT MESSAGE
4610
RIGHT SPEED SENSOR - NOT
RESPONDING PROPERLY
4611
LEFT SPEED SENSOR - NOT
RESPONDING PROPERLY
31210090
DESCRIPTION
The controller detects an overvoltage or
undervoltage condition. Overvoltage
threshold is 35V, undervoltage threshold
is 9,5V .
The controller detects an overvoltage or
undervoltage condition. Overvoltage
threshold is 35V, undervoltage threshold
is 9,5V .
The batteries are deeply discharged.
DESCRIPTION
A problem has been detected with the
right drive motor speed sensor (encoder).
A problem has been detected with the left
drive motor speed sensor (encoder).
– JLG Lift –
SECTION 10 - DIAGNOSTIC TROUBLE CODES
• Check for Ground and Platform Emergency Stop
connections
• If the fault appears at start up or during standby :
check that no external device is connected to the
batteries, creating down-going pulses. Refer to a
qualified JLG mechanic to know the approved
options on the machine.
• If no voltage transient is detected on the supply line
and the fault appears every time the key is switched
ON : Replace the Master controller.
• Check if the fault appears during traction accelera-
tion or driving hydraulic functions (undervoltage
condition detected) : check battery charge; check
for damaged batteries, battery cables and connec-
tions
• Check if the fault appears during traction braking
(overvoltage condition detected) : check line con-
tactor contact, battery power cable connection.
• Check for Ground and Platform Emergency Stop
connections
• If the fault appears at start up or during standby :
check that no external device is connected to the
batteries, creating down-going pulses. Refer to a
qualified JLG mechanic to know the approved
options on the machine.
• If no voltage transient is detected on the supply line
and the fault appears every time the key is switched
ON : Replace the Slave controller.
• Check if the fault appears during traction accelera-
tion or driving hydraulic functions (undervoltage
condition detected) : check battery charge; check
for damaged batteries, battery cables and connec-
tions
• Check if the fault appears during traction braking
(overvoltage condition detected) : check line con-
tactor contact, battery power cable connection.
• Recharge batteries.
• Check for damaged batteries, battery cables or
connections.
• Check battery charger function. Be sure to observe
indicators for at least 30 seconds.
• Check the right motor encoder wiring and connec-
tions.
• Check the harness for proper installation (refer to
Section 11).
• Check the left motor encoder wiring and connec-
tions.
• Check the harness for proper installation (refer to
Section 11).