SECTION 2 - GENERAL SERVICE INFORMATION
For a correct reading of pressure relief values, the
machine must be operated from the platform console at
maximum speed (max. travel of the joysticks). Read the
pressure values when the cylinders are at end of stroke or
when the structure is fully swung either to the left or to the
right. When checking pressure relief value of the swing
function, the mast must be fully lowered.
In case of noisy operation of the pressure relief valve
when cylinders are at end of stroke, bleed the air from the
valve.
Refer to Sections 7 and 9-8 of this manual for further infor-
mation.