SECTION 10 - DIAGNOSTIC TROUBLE CODES
DTC
FAULT MESSAGE
33103
JIB LIFT DOWN VALVE -
SHORT TO GROUND
33104
JIB LIFT DOWN VALVE - OPEN
CIRCUIT
33105
JIB LIFT DOWN VALVE -
SHORT TO BATTERY
33297
LEFT BRAKE - SHORT TO
GROUND
33300
LINE CONTACTOR COIL -
OPEN CIRCUIT
33304
RIGHT BRAKE - SHORT TO
GROUND
33355
STEER VALVE - SHORT TO
GROUND
33356
STEER VALVE - OPEN CIRCUIT
10-10
DESCRIPTION
The Jib Lift Down valve driver is shorted
or the valve coil is faulty (open) or discon-
nected.
The Jib Lift Down valve coil is faulty or dis-
connected or the coil driver is faulty.
The Jib Lift Down valve coil driver output
is shorted to +Vbatt.
The left brake positive output supply is
detected shorted to -Vbatt.
The EV1 valve driver is not able to drive
the load (cannot close).
The right brake positive output supply is
detected shorted to -Vbatt.
The Steer valve driver is shorted or the
valve coil is faulty (open) or discon-
nected.
The Steer valve coil is faulty or discon-
nected or the coil driver is faulty.
– JLG Lift –
CHECK
• Check the valve driver output CR3(33) for a short
circuit with -Vbatt.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve coil connections and wiring for
short to +Vbatt.
• Check the valve coil for correct impedance (refer to
Section 8).
• Check the left brake positive driver output CR3(2)
for a short circuit with -Vbatt.
• Check the brake coil for correct impedance (refer to
Section 8).
• If the wiring and the coil are correct, the driver cir-
cuit is damaged : replace the Slave controller.
• The device or its driving circuit is damaged, replace
the controller.
• Check the right brake positive driver output CR2(2)
for a short circuit with -Vbatt.
• Check the brake coil for correct impedance (refer to
Section 8).
• If the wiring and the coil are correct, the driver cir-
cuit is damaged : replace the Master controller.
• Check the valve driver output CR3(11) for a short
circuit with -Vbatt.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
31210090