DTC
FAULT MESSAGE
33358
FLOW DIRECTION VALVE -
SHORT TO GROUND
33359
FLOW DIRECTION VALVE -
OPEN CIRCUIT
33362
SWING VALVE - OPEN CIR-
CUIT
33365
MAST VALVE - OPEN CIRCUIT
33366
PROPORTIONAL RELIEF
VALVE - SHORT TO BATTERY
33367
PROPORTIONAL RELIEF
VALVE - SHORT TO GROUND
33368
PROPORTIONAL RELIEF
VALVE - OPEN CIRCUIT
33381
MASTER MODULE OUTPUTS -
SHORT TO BATTERY
31210090
DESCRIPTION
The Flow Direction valve driver is shorted
or the valve coil is faulty (open) or discon-
nected.
The Flow Direction valve coil is faulty or
disconnected or the coil driver is faulty.
The Swing valve coil is faulty or discon-
nected or the coil driver is faulty.
The Mast valve coil is faulty or discon-
nected or the coil driver is faulty.
The Proportional Relief valve driver output
is detected short to +Vbatt.
The Proportional Relief valve driver output
is shorted.
The Proportional Relief valve coil is faulty
or disconnected.
One of the Master module On/Off outputs
is detected short to +Vbatt.
– JLG Lift –
SECTION 10 - DIAGNOSTIC TROUBLE CODES
• Check the valve driver output CR3(34) for a short
circuit with -Vbatt.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the following Slave controller driver output
CR3(23) for a short circuit with +Vbatt.
• Check the valve coil for correct impedance (refer to
Section 8).
• If the harness and the coil are correct and if the fault
appears at start up : Replace the Slave controller.
• Check the valve driver output CR3(23) for a short
circuit with -Vbatt.
• If the wiring is correct, the driver circuit is damaged
: replace the Slave controller.
• Check the valve coil connections and wiring for
interruptions.
• Check the valve coil for correct impedance (refer to
Section 8).
• Replace the Slave controller if the coil and its har-
ness are correct.
• Check the following Master controller driver out-
puts for a short circuit with +Vbatt : Beacon
CR2(11), Line Contactor CR2(8).
• Check the line contactor coil for correct impedance
(refer to Section 8).
• If the harness and the devices are correct and if the
fault appears at start up : Replace the Master con-
troller.