POTS Connections

To connect POTS, refer to
1. Trim each wire to length. Identify each pair in the service cable.
2. Remove the rubber grommet from the housing and insert the POTS cables through the
3. Flip the POTS pivot connector to the "up" position.
4. Insert the appropriate wires TIP (green) and RING (red).
5. Flip the pivot connectors to the "down" position.
6. Replace the rubber grommet in the housing.
NOTE
The RJ-11 POTS ports are used for testing only.
2-18
Figure 2-11
grommet.
to complete the following steps:
TOTAL ACCESS 372
1287722G1
TELEPHONE TROUBLESHOOTING:
1. Identify the bad line (POTS 1-8).
2. Plug any working phone into
the appropriate jack.
If the telephone works, the unit
is functioning normally.
If the telephone does not work,
contact your service provider.