Total Access 300 Series Small Business Unit ONT Installation and Maintenance Guide

OptiTap Installation

!
CAUTION
Ensure that fiber used is UL Listed Optical Fiber Cable suitable for this
application, and does not contain any metallic members or other electrical
conductive materials.
To install the OptiTap Connector to the ONT, refer to
and complete the following steps:
1. Remove the protective Covers on the OptiTap Connector.
2. Remove the Jam Nut from the OptiTap Cable Connector.
3. Unscrew the Fiber Optics Sleeve from the Fiber Optics Cable.
4. Push the Fiber Optics Cable through the rubber grommet on the bottom of the housing.
5. Reattach the Fiber Optics Sleeve to the OptiTap Cable Connector.
6. Attach the Mounting Bracket (P/N 32681833-1E) to the base of the housing using the two
7. Slide the OptiTap Connector through the Mounting Bracket and secure using the Jam
2-24
screws provided.
Nut.
Jam Nut

Figure 2-15. OptiTap Installation

Figure 2-15
and
Figure 2-16
Mounting
Bracket
OptiTap Cable
Connector
Fiber Optics
Sleeve
Fiber Optics
Cable
on page 2-25