4. TROUBLESHOOTING
4.2

Messages for Notification

In the IP Handset and in the Web interface of the Communication Unit you can see a list of events.
The list below shows the messages for notification that may appear in connection with the Safety
Voice function.
Notification
Code
0x10500
Safety Voice registration has failed, ei-
ther eMLPP registration has not suc-
ceeded. Call Waiting could not be
enabled or it has taken too long time in
total (5 minutes).
0x10501
Safety voice handset is not connected.
0x10502
Safety voice settings are changed.
0x10503
Safety voice settings are changed.
0x10600
Alarm Panel is not connected.
0x10601
More than one Alarm Panels are con-
nected.
0x10602
Distress button error.
Message
14
Remedy
Contact your SIM provider and verify eM-
LPP is enabled on the SIM card and that
Call Waiting service is commissioned.
Check if Safety Voice handset is con-
nected correctly to the LAN (PoE) inter-
face. If it is connected correctly, please
contact your dealer.
Restart the Communication Unit to en-
able the service.
Restart the Communication Unit to dis-
able the service.
Check if Alarm Panel is connected cor-
rectly to the Communication Unit.
Make sure only one Alarm Panel is con-
nected.
Restart the Communication Unit and
Alarm Panel. If the problem persists, con-
tact your dealer.