3. USING THE SYSTEM
3.4
Displaying Faults
If there is a fault in the connected equipment or network, the buzzer in the Alarm Panel sounds
and the display of the Alarm Panel shows "Fault".
Note: The Fault indicator is also lit if Safety Voice is disabled in the connected Communication
Unit.
If the Alarm Panel loses connection to the Communication Unit, the dot after FB disappears and
"FB" and "Fault" are flashing.
If the Fault indicator is shown, you can check the list of active events in the IP Handset as follows:
1. From the IP Handset, press the Enter key to open the main
menu.
2. Select [Notifications].
If there are more than one event occurred in the IP Handset or
Communication Unit, the display shows a list. Select an event
in the list to see details.
You can also see a list of active events and an event log in the built-
in web interface of the Communication Unit. For details, see the Op-
erator's Manual (OME-57050) for your FELCOM251/FELCOM501.
10