TESTS
1) Water Inlet Valve Test
Turn power off. If the water level rises inside the tank, the Water Inlet Valve is leaking. Disconnect
wires from the Water Inlet Valve coil and connect a 2 wire line cord to the terminals. Plug it into a
115V outlet. If water flows in and stops when you pull it out, the Valve is working fine. Repeat this
test a few times. The problem may be in the Probe. If the water does not flow in when the cord is
plugged into an electrical outlet, the Solenoid coil may be damaged, opened or the valve may
have an obstruction preventing the water from flowing in. Clean or replace it.
A Check Valve is installed to prevent backflow.
To check proper function of Check Valve, disconnect water line from the Check Valve, check for
dripping from the disconnected end of the Check Valve. If it leaks replace it.
2) Water Level Probe Test
If there is a lack of water, you will get an error message on the LCD window. Check the probe as
follows:
Turn on the power and water supply. Check inside the tank to make sure the water is not touching
the Probe. Pull the wire and terminal out of the Probe rod. If water starts f l owing into the tank, the
Probe may be grounded, due to excessive liming. Check with Ohm meter. Clean or replace.
3) Relay Test
Turn Power Switch ON.
Measure Voltage across Output "COM" to Ground. Should read 120 V.
Measure Voltage across Input "NO" to Ground. Should read 120 V.
Measure Voltage across Input to Coil. Should read 24 VDC.
4) Thermistor Test
Thermistor senses the water temperature in the tank. If either of the two leads is shorted to the
metal housing, an error message will result. Check with an ohm meter if either lead is grounded.
To check calibration of the thermistor, use an Ohm meter to check resistance values at the below
temperature.
If the above values vary 2 Ohm or more, replace the thermistor.

RECOMMENDED PREVENTIVE MAINTENANCE

1. CHECK ALL DISPENSE VALVES FOR LIME BUILD-UP.
•Drain The Water Tank To Just Below The Level Of The Dispense Valves.
•Remove The Valves And Clean. ( You Can Take
These Valves Apart By Hand As Shown).
•Replace The Assembly As Needed (L467A).
•Replace The Valve Into The Tank And Refill tank.
13
CHECK VALVE
ASS'Y L463A
HOSE NUT
ASS'Y K491A
WATER INLET
VALVE L462A
WATER FLOW

Advertisement