normal operation. If the offending Hopper is not rinsed after the first Rinse warning additional Rinse Warnings will be generated every five
minutes until the respective Hopper is rinsed. The default setting for this parameter is OFF.
13. Rinse Lockout Status - This parameter determines whether the Rinse Lockout Option is turned ON or OFF. If this option is ON the system
generates a Rinse Lockout if a Hopper has dispensed and has not been Rinsed for a period of time greater than that defined by the Rinse
Lockout Time. Once a Hopper enters Rinse Lockout the LED's of the Dispense Keys related to that Hopper will turn OFF thus indicating that
the Hopper will no longer dispense. The default setting for this parameter is OFF.
14. Rinse Lockout Time – This parameter determines the length of time required before entering Rinse Lockout. The minimum Rinse Lockout
Time = 1 hour. The maximum Rinse Lockout Time is 12 hours. The default value for this parameter is 4 hours.
15. Water Temperature Set Point – This parameter determines the required reservoir tank water temperature. The minimum Water
Temperature Set Point is 140°F. The maximum Water Temperature Set point is 203°F. The default value for this parameter is 190°F.
16. Low Water Temperature Lockout Status – This parameter determines whether the Low Water Temperature Lockout Option is turned ON
or OFF. If this option is ON the system generates a Low Water Temperature Lockout if the present water temperature is below the value
defined by the Low Water Temperature Lockout Set Point. Once a Hopper enters Low Water Temperature Lockout, all of the Dispense Key
LED's will turn OFF thus indicating that the system will no longer dispense. The default setting for this parameter is OFF.
17. Low Water Temperature Lockout Set Point – This parameter determines the minimum reservoir tank water temperature allowed before
entering Low Water Temperature Lockout. The minimum Low Water Temperature Lockout Set Point is 125°F. The maximum Low Water
Temperature Lockout Set point is 203°F. The default value for this parameter is 140°F.
18. Sleep Mode Status – This parameter determines whether the Sleep Mode Option is turned ON or OFF. If this option is ON and the system
has not dispensed for four hours the system will enter Sleep Mode. Once in Sleep Mode the system will reduce the required Water
Temperature to equal that defined by (10°F + Low Water Temperature Lockout Set Point). The default setting for this parameter is OFF.
19. Hopper Status – This parameter determines the whether a selected Hopper is turned ON or OFF. If a Hopper is ON then the Auger Motor,
Mixer Motor, and Dump Solenoid status checking is enabled and the Hopper is allowed to dispense. If a Hopper is OFF then Auger Motor,
Mixer Motor, and Dump Solenoid status checking is disabled and the LED's of the Dispense Keys related to that Hopper will turn OFF thus
indicating that the Hopper will no longer dispense. The default setting for this parameter is ON.
20. Blower Diagnostics – This parameter will monitor the status of the blower motor and display a warning if it senses a problem. The default
setting for this parameter is OFF.
21. Displayed Units – This parameter determines whether the displayed units of measure are English or Metric. If the Displayed Units
parameter is set to English then all temperatures are displayed as Degrees Fahrenheit and all volumes are displayed as Fluid Ounces. If
the Displayed Units parameter is set to Metric then all temperatures are displayed as Degrees Celsius and all volumes are displayed as
Milliliters. The default setting for this parameter is English.
22. Clock Settings – Need to set clock date (DAY, MONTH and YEAR) at the beginning life of the machine.
23. Default Values – Resets all parameters to FACTORY SETTINGS.