Status information
5.3

Status information - Warnings

"Warning"
In the
state, the red error LED flashes and the green 7-segment display alternately shows
the status and the warning number.
Display
Warnings
on the
in NDrive:
servo:
0
WARNING_0
1
ILLEGAL STATUS
2
SAFE_IN
3
4
5
6
MOTORTEMP
7
DEVICETEMP
8
Vout_Sat
9
I_PEAK
A
RACEWAY
B
C
D
E
F
BALLAST
Attention:
Warning F is a device-dependent warning (without function for BAMOCAR).
Example: Warning 7
Illuminated display:
Version: 2021 / V2
Meaning:
Device detection inconsistent
RUN Signal disturbed, EMI
RFE input inactive (without RUN input active)
Engine temperature > (I-red-TM or 93 % of M-Temp)
Unit temperature > 87 % of limit
Limit of existing voltage output reached
Overcurrent 200 %
Resolution range of the speed measurement exceeded
Ballast circuit > 87 % overloaded
FAULT LED red - flashing
The display alternates between status
and warning number 7
Page: 48
Address:
RegID 0x8FH
Bit 16
Bit 17
Bit 18
Bit 19
Bit 20
Bit 21
Bit 22
Bit 23
Bit 24
Bit 25
Bit 26
Bit 27
Bit 28
Bit 29
Bit 30
Bit 31
DEVICETEMP
Engine temperature
> (I-red-TM or 93 % of M-Temp)