Battery Connection - Unitek BAMOCAR-PG-D3-400/400 Manual

Digital battery - motor controller for ec servo motor, for ac asynchronous servo motor
Hide thumbs Also See for BAMOCAR-PG-D3-400/400:
Table of Contents

Advertisement

Electrical installations
3.8

Battery connection

The maximum connection voltage (battery voltage) 450 V= (780 V=),
do not exceed even for a short time - risk of destruction!
Error message: OVERVOLTAGEF1
= slow-blow fuse
Programming an output for the pre-charge:
The output Dout1 switches the relay K3 if the DC link voltage (DC BUS) is greater than variable 1.
Attention:
The power connection has no reverse polarity protection.
If the polarity of the power connection is reversed, the unit may be destroyed.
Type
Battery connection
250/400
Battery connection <2 m, from 2 to 10 m make connection stronger.
Use additional capacity from 10 m! Lay positive and negative cables in parallel.
Maximum connection cross-section 50 mm2, cable lug for M10.
Version: 2021 / V2
Connection cross-section
mm²
AWG
35
1
Page: 32
DC link capacitor C-ZW
at 400 V
320 µF
at 700 V
320 µF
Discharge resistance R-ZW:
50 kΩ
Series resistor
RV approx. 40 Ω, 50 W
Charging current via K2:
< 20 A
Attention:
Enable (RUN) only after the main
contactor K1 has been switched.
Fuse AT
Drive-
Contactor size
250
BAMOCAR-PG-D3-700/250, 400

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Bamocar-pg-d3-700/250Bamocar-pg-d3-700/400

Table of Contents