Electrical installations
3.9
Motor power connection
For synchronous motors (brushless DC motors, EC motors) and AC servo motors
with feedback encoder.
Follow-up
Cable designation
Motor phases
Connection terminal
Minimum cable cross-section
Type BAMOCAR
Cross section mm²
AWG
Motor choke
Only necessary from a shield capacity of >5 nF / approx. 25 m motor cable.
Ferrite rings
In case of HF interference coupling on Sensor systems, slide ferrite rings over the motor cable.
Shield connection
Flat connection at the control cabinet input or machine/vehicle frame.
Flat or shortest possible connection on the motor side.
If the motor cables are long, connect the motor cable shields to earth (mounting frame)
several times (e.g. earth connection every 2 metres).
Version: 2021 / V2
M1
M2
M3
U
V
W
XB:2
XB:3
XB:4
250
400 Motor choke
Only necessary from a screen capacity of
25
35
of >5 nF.
1
approx. 25 m motor cable
Page: 33
Motor cable
3 cores + protective earth
single shielded, for 1000 V=
Shield capacitance 150 pF/m
Minimum cross-section s. Table
BAMOCAR-PG-D3-700/250, 400