Electrical installations
3.4
EMC
The units comply with the EC Directive 2004/108/EC in the standards EN61800-3 under the following
installation and test conditions
Mounting:
Unit is conductively mounted on a blank mounting plate 500 x 500 x 5 mm.
Mounting plate connected to earth via 10 mm².
Motor housing connected to earth via 10 mm².
Device ground X-AGND connected to mounting plate via 1.5 mm².
Unit PE screw X3:6 connected to mounting plate via cable 4 mm².
Control connections:
Signal lines shielded, analogue signal lines twisted and shielded
Shield: Flat contact on mounting plate (earth)
Battery connection:
12.. 360 V DC voltage
Version: 2021 / V2
Page: 26
BAMOCAR-PG-D3-700/250, 400