Replace High Pressure Limit Switch

DISCONNECT POWER AND FOLLOW ALL LABELED WARNINGS.
NOTE The pressure switch can either be replaced by brazing in a
new part of ordering a "bolt-on" kit that attached to the service
port. The method below describes the use of the bolt-on kit.
Step 1.
Attention! Please read these instructions before attempting installation.
Always turn o all the power to the unit.
Step 2.
Remove front and side panels for a better access.