Replace The Outdoor Fan 12K/24K - Friedrich VRP12K Service And Parts Manual

Hide thumbs Also See for VRP12K:
Table of Contents

Advertisement

Replace the Outdoor Fan 12k/24k

Caution: Wait for 2 minutes after removing power from the unit to allow capacitors to discharge before handling the MCS board,
disconnecting leads or connectors, or taking ohm readings.
1. Remove unit from closet.
2. Remove front, left and and right side access panels.
3. Unplug molex harness from cabinet junction (white 3 pin plug)
4. Remove nuts from fan motor mount at 4 places.
5. Remove 8 screws from fan inlet ring.
6. Fan assembly can be removed through the right side of the
unit.
7. Remove fan blade from motor shaft.
8. Remove motor from mount.
9. Install new fan motor in reverse sequence.
129
COMPONENT TESTING
Molex Connector
Mounting Bolt
(4 places)
Figure 607 (Outdoor Fan)