Friedrich VRP12R Service And Parts Manual (221 pages)
Brand:
Friedrich
| Category:
Heat Pump
| Size: 39 MB
Table of Contents
Table of Contents
2
Introduction
6
VRP® Variable Speed System Vs. Fixed-Speed System
7
Freshaire™ Conditioned Fresh Air
8
Reheat Coil - Augments Vrp's Dehumidification Capability
9
Important Safety Information
10
Personal Injury or Death Hazards
12
Model and Serial Number Identification Guides
13
Specifications
14
Cooling Performance
14
12K Extended Cooling Performance Data
15
12 And 24K Extended Heating Performance Data
17
Air Flow Data -12K and 24K
18
Air Flow Data -36K
19
Electrical Data
20
12K and 24K Unit Dimensional Data
21
36K Unit Dimensional Data
22
12K and 24K Unit Installation Dimensional Data
23
12K and 24K Accessories Dimensional Data-Louvers & Return Access Door
24
12K and 24K Accessories Dimensional Data - Wall Plenums
25
36K Accessories Dimensional Data-Louvers
26
Operation
27
Sequence of Operations
27
Wall Controller Operation
28
Freshaire Control
30
Startup-Process
31
Firmware Overview
31
VPXWC Overview
33
Wall Controller Firmware
34
FMC Firmware Via Wall Controller (WC)
35
MCS Firmware Via Wall Controller (WC)
36
VRPXWC Operating Modes
37
Fan Operating Modes
38
Cooling Operating Mode
40
Heating Operating Mode
41
Button Light Functions
42
VRPXWC Button Sequences
43
Component Identification
44
Indoor Coil 12 & 24K
45
Indoor Coil 36K
46
Indoor Blower
47
Outdoor Coil
48
Outdoor Fan
49
Compressor
50
Electric Heater
51
Electronic Expansion Valve
52
4-Way Reversing Valve
53
Remaining Components (Side View)
54
VRP Control Boards
55
Heater Board
55
Motor Control Sub-System (MCS)
58
Compressor Control
61
EEV Control
62
Reheat Control
63
Condensate Base Pan Heater
64
Condensate Sump Pan - 36K Models
65
Installation
66
VRP Required Minimum Clearances
67
Installation Orientations 12&24K
68
Installation Orientations 36K
69
Exterior Wall Opening Dimensios 12 &24K
70
Exterior Wall Opening Dimensios 36K
72
Interior(Closet) Wall Opening Dimensions 12 & 24K
73
Interior(Closet) Wall Opening Dimensions 36K
74
Preliminary Plumbing
75
Wall Plenum Installation 12 & 24K
76
Wall Plenum Installation 36K
80
Louver Installation
84
Final Wall Plenum and Architectual Louver Installation
85
Unit Installation
86
Final Unit Installation Overview
87
Side Configuration Installation
88
Unit Drain Installation
89
Ductwork Installation
90
Wall Controller Installation 12 & 24K
91
Wall Controller Installation 36K
95
Electrical Installation 12 & 24K
97
Return Air Door Installation12 & 24K
99
Return Air and Door Installation 36K
100
Freshaire System Set-Up and Operation
101
Final Installation Checklist
102
Return Air Grille/ Access Panel VRPXAP1
103
R-410A Sealed System Repair
104
Refrigerant Charging
105
Undercharged Refrigerant Systems
106
Overcharged Refrigerant Systems
107
Restricted Refrigerant System
108
Sealed System Method of Charging/ Repairs
109
Compressor Replacement
110
Compressor Replacement -Special Procedure in Case of Compressor Burnout
111
Replace the Reversing Valve
112
Replace the Condensor Coil 12K/24K
113
Replace the Condensor Coil 36K
114
Replace the Evaporator Coil 12K/24K
115
Replace the Evaporator Coil 36K
116
Replace the Evaporator Coil Drain Pan
117
External Static Pressure
118
Component Testing
121
Electronic Expansion Valve (EEV)
121
Reversing Valve Description and Operation
122
Testing the Reversing Valve Solenoid Coil
123
Checking the Reversing Valve
124
Touch Test Chart : to Service Reversing Valves
125
Compressor Checks
126
Check the Outdoor Fan 12K/24K
127
Check the Outdoor Fan 36K
128
Replace the Outdoor Fan 12K/24K
129
Replace the Outdoor Fan Motor36K
130
Check the Indoor Fan 12K/24K
131
Check the Indoor Fan 36K
132
Replace the Indoor Fan 12K/24K
133
Replace the Indoor Fan 36K
134
Check the Heating Elements
135
Replace the Heating Elements
136
Mcs Motor Control System Board Pin out
137
Mcs Motor Control System Board Replacement
138
Fmc Board Pin out
139
FMC Board Replacement
140
Heater Board Pin out
141
Heater Board Replacement
142
Thermistor Locations
143
T8 (Return Air Sensor)
143
T1 (Evaporator Coil in Sensor)
144
T5 (Evaporator Coil out Sensor)
144
T9 (Discharge Air Sensor)
145
T2 (Liquid Heat)
146
T6 (Liquid Cool)
146
T10 (Outdoor Ambient Air Sensor)
147
T7 (Cond. Coil Sensor)
148
T4 (Comp. Discharge)
149
T3 (Comp. Suction)
150
Thermistor Values
151
Thermistor Part Numbers
152
Check High and Low Pressure Limit Switches
153
Replace High Pressure Limit Switch
154
Troubleshooting
156
VRP Troubleshooting Map
156
Required Tools
157
Required Skills
158
Troubleshooting by Rule out Methodology
158
Troubleshooting Flowchart
159
Wall Controller Not "Smart
160
Verify Wall Controller Firmware
161
Verify FMC Firmware
162
Verify MCS Firmware
163
Check for Power
164
Diagnostic Code Check
165
Diagnostic Code (Temperature Based)
167
Diagnostic Codes (Voltage/ Amperage)
168
Voltage/Amperage Related Diagnostics -ODF Rule out
169
Voltage/Amperage Related Diagnostics - MCS Operational Lights
169
Configuration/Communication Diagnostic Codes
170
Configuration/Communication Diagnostic Codes 27 & 43
170
Configuration/Communication Diagnostic Codes - 39 (IDF Comm Error)
171
Diagnostic Codes
172
Updating Vrp Firmware
176
FMC Manual Update Process - Remove SD Card from FMC Load on a PC or Laptop
176
FMC Update Process - Loading New Firmware
179
VRP Remote Upgrade Procedure
187
Retrieving VRP Data
193
Wiring Diagrams
196
12-24K Btu (208/230V 7.5&10.0 Kw)
196
12-24K Btu (208/230V 2.5, 3.4, & 5.0 Kw)
197
12-24K BTU (265V 2.5, 3.4, & 5.0 Kw)
198
12-24K BTU (265V 7.5 & 10 Kw)
199
36K Btu - 208/230V
200
Parts Catalog
201
12K Main Diagram
201
12K Control Box Diagram
204
12K Control Box Diagram
205
24K Main Diagram
206
24K Control Box Diagram
209
Accessories
216
Accessories
217
CUSTOMER SATISFACTION and QUALITY ASSURANCE
221
Friedrich Authorized Parts Depots
221
Advertisement
Friedrich VRP12R Service & Parts Manual (143 pages)
Brand:
Friedrich
| Category:
Air Conditioner
| Size: 8 MB
Table of Contents
Table of Contents
2
Introduction
5
Part Load Performance
6
VRP® Variable Speed System Vs. Fixed-Speed System
7
Freshaire™ Conditioned Fresh Air
8
Reheat Coil - Augments Vrp's Dehumidification Capability
9
Important Safety Information
10
Personal Injury or Death Hazards
12
Model and Serial Number Identification Guides
13
Specifications
14
Cooling Performance
14
12K/24K Extended Cooling Performance Data
15
And 24K Extended Heating Performance Data
16
Air Flow Data -12K and 24K
17
Electrical Data
18
12K and 24K Unit Dimensional Data
19
12K and 24K Unit Installation Dimensional Data
20
12K and 24K Accessories Dimensional Data-Louvers & Return Access Door
21
12K and 24K Accessories Dimensional Data - Wall Plenums
22
Operation
23
Sequence of Operations
23
Freshaire Control
24
Component Identification
25
Indoor Coil 12 & 24K
26
Indoor Blower
27
Outdoor Coil
28
Outdoor Fan
29
Compressor
30
Electric Heater
31
Electronic Expansion Valve
32
4-Way Reversing Valve
33
Remaining Components (Side View)
34
VRP Control Boards
35
Main Controller
36
Compressor Control
37
EEV Control
38
Reheat Control
39
Installation
40
VRP Required Minimum Clearances
41
Installation Orientations 12&24K
42
Exterior Wall Opening Dimensions 12 &24K
43
Interior(Closet) Wall Opening Dimensions 12 & 24K
44
Preliminary Plumbing
45
Wall Plenum Installation 12 & 24K
46
Louver Installation
50
Final Wall Plenum and Architectual Louver Installation
51
Unit Installation
52
Final Unit Installation Overview
53
Side Configuration Installation
54
Unit Drain Installation
55
Ductwork Installation
56
Wall Controller Installation 12 & 24K
57
Return Air Door Installation12 & 24K
60
Freshaire System Set-Up and Operation
61
Final Installation Checklist
62
Troubleshooting
63
VRP Troubleshooting Map
63
Required Tools
64
Required Skills
65
Troubleshooting by Rule out Methodology
65
Diagnostic Codes
66
Check for Power
70
Diagnostic Code (Temperature Based)
71
R-410A Sealed System Repair
72
Refrigerant Charging
73
Undercharged Refrigerant Systems
74
Overcharged Refrigerant Systems
75
Restricted Refrigerant System
76
Sealed System Method of Charging/ Repairs
77
Compressor Replacement
78
Compressor Replacement -Special Procedure in Case of Compressor Burnout
79
Replace the Reversing Valve
80
Replace the Condensor Coil 12K/24K
81
Replace the Evaporator Coil 12K/24K
82
Replace the Evaporator Coil Drain Pan
83
Component Testing
84
Electronic Expansion Valve (EEV)
84
Reversing Valve Description and Operation
85
Testing the Reversing Valve Solenoid Coil
86
Checking the Reversing Valve
87
Testing the Reheat Valve Solenoid Coils
88
Touch Test Chart : to Service Reversing Valves
89
Compressor Checks
90
Check the Outdoor Fan 12K
91
Replace the Outdoor Fan 12K
92
Check the Indoor Fan
93
Replace the Indoor Fan 12K/24K
94
Check the Heating Elements
95
Replace the Heating Elements
96
Driver Board Pin out
97
Driver Board Replacement
98
Check RS-485 Converterboard
99
Fmc Board Pin out
100
FMC Board Replacement
101
Heater Board Pin out
102
Heater Board Replacement
103
Thermistor Locations
104
T8 (Return Air Sensor)
104
T1 (Evaporator Coil in Sensor)
105
T5 (Evaporator Coil out Sensor)
105
T9 (Discharge Air Sensor)
106
T2 (Liquid Heat)
107
T6 (Liquid Cool)
107
T10 (Outdoor Ambient Air Sensor)
108
T7 (Cond. Coil Sensor)
109
T4 (Comp. Discharge)
110
T3 (Comp. Suction)
111
Thermistor Part Numbers
112
Replace Transformer
113
Check High and Low Pressure Limit Switches
114
Check Basepan Heater
115
Updating Vrp Firmware
116
FMC Manual Update Process - Remove SD Card from FMC Load on a PC or Laptop
116
FMC Update Process - Delete Current Files or Format SD Card
117
FMC Update Process - Unzip Files to Blank or Formatted SD Card
118
FMC Update Process - Verify Files on SD Card Drive
119
FMC Update Process - Loading New Firmware
119
Wiring Diagrams
120
Btu (E Models) (208/230V 2.5, 3.4, & 5.0 Kw)
120
BTU (E MODELS) (265V 2.5, 3.4, & 5.0 Kw)
121
Parts Catalog
122
E Models (Unit Assembly)
122
12K E Models Basepan
132
E Models (230V Electrical Controls)
133
E Models (265V Electrical Controls)
135
Accessories
137
Accessories
138
Wall Controller/ Thermostat
138
Installation Accessories and Descriptions
139
Appendix
141
Thermistor Values
141
CUSTOMER SATISFACTION and QUALITY ASSURANCE
143
Friedrich Authorized Parts Depots
143
Friedrich VRP12R Installation & Operation Manual (41 pages)
Variable Refrigerant Packaged Heat Pump
Brand:
Friedrich
| Category:
Heat Pump
| Size: 6 MB
Table of Contents
Table of Contents
2
Warnings
3
Specifications
4
Dimensions
5
Electrical Data
6
Air Flow Data
7
Minimum Clearances
8
Installation Orientations
9
Rough Opening Dimensions
10
Preliminary Plumbing
12
Wall Plenum Installation
13
Louver Installation
17
Unit Installation
19
Drain Installation
22
Ductwork Installation
23
Wall Controller Installation
24
Electrical Connection
26
Return Air Door Installation
27
Freshaire™ System Set-Up and Operation
28
Electrical Wiring Diagrams
29
Basepan Heat
33
Final Installation Checklist
34
Service and Warranty
35
Accessories
36
Diagnostic Error Codes
38
VRP Limited Warranty
39
Advertisement
Advertisement
Related Products
Friedrich VRP12K
Friedrich VRP12K/R
Friedrich VRP24K
Friedrich VRP24R
Friedrich VRP36K
Friedrich VRP7k
Friedrich VRP7r
Friedrich VPR VRP07K
Friedrich VPR VRP07R
Friedrich VRP24K/R
Friedrich Categories
Air Conditioner
Heat Pump
Dehumidifier
Thermostat
Air Cleaner
More Friedrich Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL