Siemens SITRANS FS230 Compact Operating Instructions page 103

Ultrasonic flowmeters
Table of Contents

Advertisement

Description
Relative humidity
Mechanical environment resistance class 4M3 for industrial enclo‐
sure
Climatic resistance class 4K4H
EMC performance
Table 7-28
Description
Process medium tempeature within the acceptable temperature
range for the sensors
Fluid must be sonically conductive
Operation outside the Reynolds transition region for best accuracy -
Table 7-29
Description
Approvals
Accuracy
Repeatability
Pipe size range
Wall Thickness Range
Pipe material
SITRANS FS230
Compact Operating Instructions, 05/2021, A5E38755607-AC
Emission
Immunity
Process medium conditions
Performance section
Technical specifications
7.9 Operating conditions
Specification
95 %
IEC 60068-2-64 test Fh: Ran‐
dom vibration
IEC 60068-2-27 test Ea and
guidance: Impact
IEC 60068-2-2 test B: Dry heat
IEC 60068-2-1 test A: Cold
IEC 60068-2-78 test Cab: Damp
heat, steady state
IEC 60068-2-14 test N: Change
of temperature
EN 55011 / CISPR-11
EN/IEC 61326-1 (Industry)
NAMUR
Specification
(-40 to 230 °C for High Tempera‐
ture 991 sensors)
-
Specification
ATEX Zone 2
IECEx Zone 2
FM Class I Div. 2
FMc Class I Div. 2
± 0.5 ... 1 % for velocities above 0.3
m/s and >10 diameters straight run
± 0.25 % (based on ISO 11631)
12.7 ... 10 m (0.5 ... 394")
0.64 ... 76.2 mm (0.025 ... 3.0")
Any sonically conductive material
(steel, plastic, aluminum, glass, ce‐
ment, ductile iron, copper)
103

Advertisement

Table of Contents
loading