Siemens SITRANS FS230 Compact Operating Instructions page 98

Ultrasonic flowmeters
Table of Contents

Advertisement

Technical specifications
7.6 Energy limitation parameters FST030
Table 7-12
Terminals
U
o
I
o
P
o
C
o
L
o
Table 7-13
U
o
I
o
P
o
C
o
L
o
L
/R
o
Table 7-14
Terminals
U
o
I
o
P
o
98
I/O connections active - wallmount enclosure
HART active
4, 5
28 V DC
85 mA
584.5 mW
Group IIC
72 nF
Groups IIB, III
639 nF
Group IIA
2139 nF
Group IIC
1.64 mH
Groups IIB, III
16.4 mH
Group IIA
36.0 mH
Output parameters - industrial enclosure
External DSL connections
17.42 V DC
459 mA
2000 mW
Group IIC
338 nF
Groups IIB, III
1969 nF
Group IIC
134 μH
Groups IIB, III
675 μH
o
Group IIC
17.8 μH/Ω
I/O connections active - industrial enclosure
HART active
4, 5
28 V DC
85 mA
584.5 mW
Modbus
I/O 2 active
4, 5, 6, 7
8, 9
4.2 V DC
28 V DC
118 mA
87 mA
124 mW
601 mW
4200 nF
78 nF
10000 nF
645 nF
10000 nF
2145 nF
2.56 mH
1.46 mH
10.2 mH
15.7 mH
20.5 mH
34.7 mH
Modbus
I/O 2 active
4, 5, 6, 7
8, 9
4.2 V DC
28 V DC
118 mA
87 mA
124 mW
601 mW
Compact Operating Instructions, 05/2021, A5E38755607-AC
I/O 3 active
I/O 4 active
11, 12
14, 15
28 V DC
28 V DC
87 mA
87 mA
601 mW
601 mW
78 nF
78 nF
645 nF
645 nF
2145 nF
2145 nF
1.46 mH
1.46 mH
15.7 mH
15.7 mH
34.7 mH
34.7 mH
I/O 3 active
I/O 4 active
11, 12
14, 15
28 V DC
28 V DC
87 mA
87 mA
601 mW
601 mW
SITRANS FS230