Section 11 − Advanced Menu Functions; Accessing Tech Menu For Dynasty/Maxstar 210 Models - Miller Dynasty 210 Owner's Manual

Hide thumbs Also See for Dynasty 210:
Table of Contents

Advertisement

SECTION 11 − ADVANCED MENU FUNCTIONS

11-1. Accessing Tech Menu For Dynasty/Maxstar 210 Models

2
TECH
ARC
ERR
SLEP
STUC
OCV
COOL
MACH
SOFT
SERL
.
A complete Parts List is available at www.MillerWelds.com
3
4
MENU
T/CY
LOG
OFF
OFF
NORM
AUTO
RSET
WARE
NUM
1
[ARC] [T/CY] Arc Timer: Monitors hours, minutes, and cycles of
valid arc on. To view, rotate encoder. To reset, rotate encoder until
[RESET] [YES] is displayed. Press Menu button to display [RESET]
[Done]. Displays turn to [000] [000].
[ERR] [LOG] Error Log: Use to view last eight logged error events.
Each event may list multiple Error Codes. See Section 12-3.
[SLEP] Sleep Timer: Turns power off after the machine exceeds the
programmed idle time without operation. Press the Standby button to
turn power on. To set or change time, rotate encoder to desired time.
Timer range: 1, 5, 10, 20, 30, 45 minutes or one hour.
[STUC] Stick Stuck: Detects if the electrode is stuck or shorted to
the workpiece. Turns weld output off to aid in freeing the electrode.
To turn on, rotate encoder. Not recommended for air carbon arc or
large diameter electrodes.
[OCV] Open Circuit Voltage: Allows user to select between Nor-
mal (NORM) and Low open circuit voltage. Low reduces open
circuit voltage to between 8 and 15 volts. To select, turn encoder.
[COOL] Cooler Power (Optional): Selects between [OFF], [ON]
(Non CE models Only), and [AUTO]. [OFF] disables the power
supply to the receptacle. [ON] enables the power supply to the
receptacle. [AUTO] provides power to the receptacle when the
TIG process is active.
[MACH] [RESET] Machine Reset: Resets all machine values
back to factory defaults. To reset, turn encoder to [RESET] [YES].
Then press Menu button. [RESET] [DONE] will be displayed when
the reset is complete and factory defaults have been restored.
[SOFT] [WARE] Software Number: Software number and revi-
sion will be displayed.
[SERL] [NUM] Serial Number: If serial number displayed does
not match serial number of machine, see Section 12-3.
1
Menu Button
Press and hold Menu button for ap-
proximately four seconds to scroll
past User Menu to Tech Menu. Use
Menu button to cycle through
parameters that can be set.
2
Parameter Display
3
Setting Display
4
Encoder
Rotate
Encoder
to
adjust
parameter setting.
.
Dynasty 210 shown, Maxstar
menus are the same. Menu
order may vary.
To exit tech menu, press and hold
menu button approximately one
second, or turn power off.
.
Settings in the Tech Menu are
global, meaning they may
pertain to all or some of the
process.
247222-D
OM-270536 Page 55

Advertisement

Table of Contents
loading

Table of Contents