ITV0000
Series
Option
Bracket
Flat bracket assembly
P39800022
L-bracket assembly
P39800023
Tighting torque when assembling is 0.3 N·m.
14-8-4
Downloaded from
Elcodis.com
electronic components distributor
Specifications
Model
ITV001
Min. supply pressure
Max. supply pressure
0.2 MPa
Regulating pressure range
0.001 to 0.1 MPa
3.5
(Supply pressure:
Maximum flow rate
0.2 MPa)
Voltage
Power supply
Current
consumption
Voltage type
Input signal
Current type
Voltage type
Input impedance
Current type
Analog
Output signal
output
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Operating temperature range
Enclosure
Connection type
Metric size
For single
unit
Inch size
Connection size
Metric size
Manifold
Inch size
(1)
Weight
Note 1) Indicates the weight of a single unit.
For IITV00-n
Total weight (g) ≤ Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN
rail
Note 2) Specifications other than the following are optional. Pressure range: 0.1 MPa, 0.5 MPa, 0.9 MPa,
Power supply voltage: 24 VDC, Input signal: 0 to 10 VDC
Note 3) When there is a downstream flow consumption, pressure may become unstable depending on
piping conditions.
∗ When using under the conditions equivalent to IP65, connect the fitting or tube to the breathing hole
prior to use. (For details, refer to page 14-8-11 in Specific Product Precautions.)
Cable connector
Straight type
M8-4DSX3MG4
Right angle type
ELWIKA-KV4408 PVC025 2M
ITV003
ITV005
Set pressure +0.1 MPa
1.0 MPa
0.001 to 0.5 MPa
0.001 to 0.9 MPa
/min(ANR)
6
/min(ANR)
6
/min(ANR)
l
l
l
(Supply pressure:
(Supply pressure:
0.6 MPa)
0.6 MPa)
24 VDC ±10%, 12 to 15 VDC
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
0 to 5 VDC, 0 to 10 VDC
4 to 20 mADC, 0 to 20 mADC
Approximately 10 kΩ
Approximately 250 Ω
1 to 5 VDC (Load impedance: 1 kΩ or more)
Output accuracy: Within ±6% (Full span)
Within ±1% (Full span)
Within 0.5% (Full span)
Within ±0.5% (Full span)
Within 0.2% (Full span)
Within ±0.12% (Full span)/°C
0 to 50°C (With no condensation)
IP65 equivalent
Built-in One-touch fittings
z, x, c:
z, x, c:
z, c:
z, c:
ø
100 g or less (without options)
ITV009
Set pressure –1 kPa
–101 kPa
–1 to –100 kPa
2
/min(ANR)
l
(Supply pressure:
–101 kPa)
∗
ø
4
ø
5/32"
6, x:
ø
ø
4
1/4", x:
ø
5/32"
Need help?
Do you have a question about the ITV Series and is the answer not in the manual?
Questions and answers