Download Print this page

Standard Specifications - SMC Networks ITV Series Manual

Electro-pneumatic regulator
Hide thumbs Also See for ITV Series:

Advertisement

Straight type
JIS Symbol
Rated pressure
0.005 MPa
0
0
Input signal (%F.S.)
Graph (1) Input/output characteristics chart
Model
1
1000
2
2000
3
3000
Power supply
voltage
0
24 VDC
1
12 to 15 VDC
0
1
Analog output 1 to 5V DC
2
Switch output/NPN output
Switch output/PNP output
3
4
Analog output 4 to 20 mA (Sink type)
∗ Option
14-8-14
Downloaded from
Elcodis.com
electronic components distributor
Electro-pneumatic Regulator
ITV1000/2000/3000

Standard Specifications

Minimum supply pressure
Maximum supply pressure
Set pressure range
Power supply
Input signal
Right angle type
Linearity
Hysteresis
Repeatability
Sensitivity
Temperature characteristics
Output pressure
display
Ambient and fluid temperature
Enclosure
Weight
Note 1)
This range is outside
of the control (output).
Note 2)
Note 3)
100
Note 4)
Note 5)
ITV
3 0
1 0
Pressure range
1
0.1 MPa
3
0.5 MPa
5
0.9 MPa
0
Current 4 to 20 mA (Sink type)
Current 0 to 20 mA (Sink type)
1
2
Voltage 0 to 5 VDC
3
Voltage 0 to 10 VDC
4
Preset input
∗ Option
Monitor output
None (for preset input)
∗ Option
Model
Note 1)
Voltage
Current
consumption
Note 2)
Current type
Voltage type
Preset input
Current type
Input
Voltage type
impedance
Preset input
Note 3)
Analog output
Output signal
(monitor
output)
Switch output
Accuracy
Minimum unit
ITV10
ITV20
ITV30
Please refer to "Graph (1)", relation to the differences between the set pressure and input.
Additionally, refer to page 14-8-29 for the set pressure range by units of standard measured pressure.
Additionally, refer to page 14-8-29 as maximum set pressure differs on unit of standard measure.
2-wire type 4 to 20 mA is not available. Power supply voltage (24 VDC or 12 to 15 VDC) is required.
Select either analog output or switch output. Further, when switch output is selected, select either
NPN output or PNP output.
The minimum unit for ITV205
is 1PSI.
The above characteristics are confined to the static state. When air is consumed on the output side,
the pressure may fluctuate.
How to Order
0 1
2
Input
signal
Thread type
Port size
Rc
1
1/8 (1000 type)
N
NPT
2
1/4 (1000, 2000, 3000 type)
T
NPTF
3
3/8 (2000, 3000 type)
F
G
4
1/2 (3000 type)
ITV101
ITV103
ITV201
ITV203
ITV301
ITV303
Set pressure +0.1 MPa
0.2 MPa
1.0 MPa
0.005 to 0.1 MPa
0.005 to 0.5 MPa
24 VDC ± 10%, 12 to 15 VDC
Power supply voltage 24 VDC type: 0.12 A or less
Power supply voltage 12 to 15 VDC type: 0.18 A or less
4 to 20 mA, 0 to 20 mA (Sink type)
0 to 5 VDC, 0 to 10 VDC
4 points
250 Ω or less
Approx. 6.5 kΩ
Approx. 2.7 kΩ
1 to 5 VDC (Load impedance: 1 kΩ or more)
4 to 20 mA (Sink type) (Load impedance: 250 Ω or less)
NPN open collector output: Max. 30 V, 30 mA
PNP open collector output: Max. 30 mA
Within ±1% (full span)
Within 0.5% (full span)
Within ±0.5% (full span)
Within 0.2% (full span)
Within ±0.12% (full span)/°C
±3% (full span)
2
MPa: 0.01, kgf/cm
: 0.01, bar: 0.01, PSI: 0.1
0 to 50°C (with no condensation)
IP65
Approx. 250 g (without options)
Approx. 350 g (without options)
Approx. 645 g (without options)
S
Q
Pressure display unit
Note 1)
MPa
2
kgf/cm
2
∗ Please visit our SMC homepage:
3
bar
http://www.smcworld.com for the
4
PSI
latest details on our CE
5
kPa
compliant products.
∗ Option
Cable connector type
S
Straight type 3 m
L
Right angle type 3 m
N
Without cable connector
∗ Option
Bracket
B
C
∗ Option
ITV105
ITV205
ITV305
0.005 to 0.9 MPa
Note 4)
, kPa: 1
CE compliance
Q
CE compliant
Without bracket
Flat bracket
L-bracket

Advertisement