Cooling Limits; Runtime Environment Requirements - Inspur NF5260FM6 User Manual

Table of Contents

Advertisement

Only specified types of PCIe cards are supported.
PCIe SSDs are not supported.
NVDIMMs are not supported.
Middle drives are not supported.
Rear drives are not supported.
GPU configuration is not supported.

Cooling Limits

Table 11-6 Cooling Limits
Configuration
Front
Name
Drive
Storage
9 × 3.5"
configuration 1
GPU1
9 × 3.5"
Table 11-7 Cooling Limits
Configuration
Front
Name
Drive
Storage
9 × 3.5" Not
configuration 1
GPU
9 × 3.5" Not
configuration 1

Runtime Environment Requirements

This section specifies the requirements for temperature and humidity, biological
conditions, chemical substances, and mechanically reactive substances. The
device in the server room must meet these requirements during runtime.
1.
Temperature and Humidity
The temperature, dew-point temperature, and relative humidity in the server room
must meet the requirements of the server. For the specific requirements of different
servers, see the detailed description of the product documentation.
Middle
Rear
Drive
Drive
Not
Not
supported
supported
Not
Not
supported
supported
Middle
Rear
Drive
Drive
Not
supported
supported
Not
supported
supported
52
CPU
≤ 250 W Not supported
Fan redundancy is
≤ 250 W
not supported.
CPU
GPU
≤ 320 W Not
supported
≤ 250 W Fan
redundancy is
supported.
GPU
Max.
Ambient
Temperature
< 30°C
< 25°C