Connecting Alarms (Inputs 1 Through 2); Connecting A Normally Open Alarm - Bosch VEZ-221-ECCE Installation Manual

Bosch vez-221-ecce: user guide
Hide thumbs Also See for VEZ-221-ECCE:
Table of Contents

Advertisement

70
en | Alarms and Relay Connections
9.2

Connecting Alarms (inputs 1 through 2)

You can configure alarms 1 through 2 as Normally Open (N.O.)
or Normally Closed (N.C.) alarms.
9.2.1

Connecting a Normally Open Alarm

1.
Figure 9.2 N.O. - Normally Open
Ref. # User Contact Dome
1
2
2.
F.01U.164.576 | 2.0 | 2010.03
Connect the alarm to the appropriate input (1 through 2)
and ground at the AutoDome Easy II.
Normally
Open
Common
From the AutoDome Easy II main menu select Alarm
Setup>Inputs Setup, and set Alarm Input # to N.O. See the
table below for contact and condition details.
AutoDome Easy II Programmed N.O.
Circuit
Open
Closed
Installation Manual
Alarm In 1 or Alarm In 2
(Ref. #3)
Ground (Ref. #4)
Alarm Indication
Normal
Alarm
AutoDome Easy II IP
Color
Brown IN 1 or
Orange IN 2
Green
Bosch Security Systems, Inc.

Hide quick links: