Configuring Non-Supervised Alarms (Inputs 1 Through 7); Configuring A Normally Open Non-Supervised Alarm; Configuring A Normally Closed Non-Supervised Alarm - Bosch VG4 Series Installation Manual

Modular camera series
Hide thumbs Also See for VG4 Series:
Table of Contents

Advertisement

98
en | Alarms and Relay Connections
6.3

Configuring Non-supervised Alarms (inputs 1 through 7)

You can configure alarms 3 through 7 as non-supervised Normally Open (N.O.) or Normally
Closed (N.C.) alarms.
6.3.1

Configuring a Normally Open Non-supervised Alarm

1.
2.
6.3.2

Configuring a Normally Closed Non-supervised Alarm

1.
2.
F.01U.162.025 | 6.0 | 2010.03
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Figure 6.3 N.O. - Normally Open Non-supervised Connections
1
Dry Contact
2
Alarm Inputs 1 to 7
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.O. See the table below for contact and condition details.
AutoDome Programmed N.O.
Circuit
Alarm Indication
Open
Normal
Closed
Alarm
Connect the alarm to the appropriate input (1 through 7) and ground at the AutoDome.
Figure 6.4 N.C. Normally Closed Non-supervised Connections
1
Dry Contact
2
Alarm Inputs 1 to 7
From the AutoDome main menu select Alarm Setup>Inputs Setup, and set Alarm Input #
to N.C. See the table below for contact and condition details.
AutoDome Programmed N.C.
Circuit
Alarm Indication
Open
Alarm
Closed
Normal
Installation Manual
3
Dome Connector
4
Ground
3
Dome Connector
4
Ground
VG4 Modular Camera Series
Bosch Security Systems, Inc.

Hide quick links:

Advertisement

Table of Contents
loading