Push button
Used to give opening impulse to the door.
See separate installation drawing 656005.
Synchronization
Used between the operators of two single sliding doors, working together in very large openings.
Interconnecting cable required.
Open / Close function
One button impulse, will alternate between Open and Close. The door will stand open until next
impulse or can after an adjustable time delay automatically start to close even if a new impulse is
not received.
Fire alarm connection
Used to emergency open or fire close the door with mains power on.
Nurse function
Used mostly in combination as a Nurse - Bed function. Nurse opens the door to partial open position,
and bed (connected to inner or outer impulse) opens to full open position.
Nurse works in operation mode selections Exit, Auto.
The Nurse impulse has the same hold open time as partial open.
Remote Exit mode
Remotely put door into Exit via an remote system, like timer.
Emergency open impulse
Used to give opening (fireman's opening) impulse to the door in any operation mode selector setting.
With electrical emergency unit also during power failure.