Regular safety checks

To help you fulfil the national/international requirements and to avoid malfunction and risk for in-
juries, we have provided the following checklist.
Do not use if repair or adjustment is necessary.
Disconnect supply
Activate your operator and visually check, fastening and any damage of
operator and cover
cables
2
operator mode selector(s)
door and glass (stability)
Also inspect your operator and check visually for
condition of door seals and weather stripping
condition of glazing rubbers
finger protection
7
proper operation; closes slowly and smoothly
any ventilation being obstructed
Set the programme selector to OFF and check that the operator and electromechanical lock (if fitted)
work together. Also check that the lock
Activate the manual activation units
opened appropriately while you pass the entrance/exit.
Then proceed with the automatic activation units
See page 11.
Check the safety sensors
See page 12.
If you are unsure of which type of sensor you have, please contact your ASSA ABLOY Entrance Systems
representative.
If the operator is equipped with break-out system, set the programme se-
lector to AUTO mode. Push the door manually while in the escape direction
to ensure that nothing prevents the door from being open. Also ensure that
the escape route is free for use. After the test, restore the door(s) to their
Escape
normal mode of operation.
doors
If the operator is equipped with automatic opening system, shut off the
power and the door should open and remain open. Restore power and the
door should close.
Let the door close after an impulse ensuring nothing prevents the door from
closing and locking (if regulations require it).
Fire
doors
=
Take appropriate measures.
=
Contact your ASSA ABLOY Entrance Systems representative. For contact information, see last page.
16
12
when cleaning or other maintenance is to be carried out.
Daily Action
1
3
4
6
8
really secures the door.
9
, if any, and walk towards the door. Check that the door has
11
if any.
Issue 2015-10-23
5
10
in the same way.
If problem
occurs