Push button

Used to give opening impulse to the door.

Synchronization

Used between the operators of two single sliding doors, working together in very large openings.
Interconnecting cable required.

Open / Close function

One button impulse, will alternate between Open and Close. The door will stand open until next
impulse or can after an adjustable time delay automatically start to close even if a new impulse is
not received.

Fire alarm connection

Used to emergency open or fire close the door with mains power on.

Nurse function

Used mostly in combination as a Nurse - Bed function. Nurse opens the door to partial open position,
and bed (connected to inner or outer impulse) opens to full open position.
Nurse works in operation mode selections Exit, Auto.
The Nurse impulse has the same hold open time as partial open.

Remote Exit mode

Remotely put door into Exit via an remote system, like timer.

Emergency open impulse

Used to give opening impulse to the door in any operation mode selector setting as long as the op-
erator has power.

PASS (previously Flow)

The PASS function enables the operator to count how many people that pass through the door, in
and out. The value can be presented in the
ASSA ABLOY Sliding Door Manager
app.
The PASS function aids in controlling the amount of people that can enter the building. The max
restriction limit is 1 000 persons.
PASS will work in all operation mode selections (except OFF which will reset the counter).
PASS Exit Only - a function that will prevent the door from opening for incoming people when the
user defined restriction limit has been reached - will work in EXIT, AUTO and AUTO PARTIAL.
To be able to change the PASS parameters, you have to use the Sliding Door Manager app. Therefore
it is needed that the operator is equipped with an OMS BLE.
In the app it is possible to set a restriction limit for PASS Exit Only. It is also possible to set value(s)
for when to receive notifications when i.e. 50% or 75% of the restriction limit is reached. Notifications
are only received when connected to the operator through Bluetooth.