Access Codes And Flashing Light; Integrated Safety - Assa Abloy Besam SL500 User Manual

Sliding door operator
Hide thumbs Also See for Besam SL500:
Table of Contents

Advertisement

CM-No.
12-553

Access codes and flashing light

701002
1008972
*
1007926
1008140
1008773
1008132
*

Integrated safety

724462
*
1008102
To permit a safe passage between closing doors, the doors reverse immediately if an obstruction is
Art.no.
detected. They then resume their interrupted movement at low speed to check whether the obstruc-
Material
tion has disappeared or not.
-
Scale
Drawn
Date
1:1
ASE
2012-04-03
If an obstruction is detected between opening doors and surrounding walls or interior fittings, the
doors stop immediately, and then close after a time delay.
10
Done
Date
JOB
2012-11-06
Codes
Three alternative selectable codes are used.
Flashing
1
The default access is obtained by pushing the arrow symbol
light
pointing up or down for 2 seconds.
2
An optional access code can be selected where the access is
obtained by briefly pushing in turn the arrow up symbol, followed
by the arrow down symbol, followed by the arrow down symbol
Up
again and at last the arrow up. The entire code must be entered
within 3 seconds.
3
No access code.
Down
The different operation modes are selected by pushing the arrow
symbols pointing upwards or downwards. When a button is pushed
a buzzer will sound. The present selection is indicated by a blue light
to the left of the function symbol or text.
When an arrow symbol has not been pushed for 15 seconds the access
will be locked.
Flashing light
Red
Orange
Yellow
Remark
Remark
Status
Approved
Rev.
Size
Sheet
1 (1)
2.0
A3
Drawing No.
1008174
Issue 2015-10-23
A red light every other second is indicating an error
in the door operator. If the error remains after a
RESET then service is needed.
If the red light is quickly flashing 3 times per second
it is indicating an internal error in the operation
mode selector.
An orange light every other second is indicating a status
or condition that can be cleared by the owner e.g. a
break-out door is standing open.
A yellow light every other second is indicating that
maintenance is needed.
1009216-EI-4.0

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Besam sl500 tBesam sl500 sl

Table of Contents