AcuLaser C2800/C2800D/C3800/C3800D
6)
6)
6)
7)
SHIELD ASSY ESS
Kmy03074EC
3. Disconnect all the connectors on the BOARD ASSY, MAIN.
4. Loosen the clamp that secures the harness connected to CN501 connector on the BOARD ASSY,
MAIN.
5. Remove the two screws (silver, washer, 6 mm) that secure the ground wires of the HARNESS ASSY-
CON R and the HARNESS ASSY USB to the SHIELD ASSY ESS E.
6. Loosen the three screws (silver, 6 mm) that secure the right side of the SHIELD ASSY ESS to the
main unit.
7. Remove the four screws (silver, 6 mm) that secure the SHIELD ASSY ESS.
8. Pulling out the harnesses through the hole in the SHIELD ASSY ESS E, remove the SHIELD ASSY
ESS from the main unit.
DISASSEMBLY/REASSEMBLY
7)
8)
7)
7)
4)
4)
3)
3)
5) 5)
3)
Disassembly/Reassembly
Revision C
291
Confidential