AcuLaser C2800/C2800D/C3800/C3800D
LATCH FRONT
4)-2
4)-1
4. Hold down the tabs to release the LATCH FRONTs, and remove the LATCH FRONTs from the
PLATE LATCH.
DISASSEMBLY/REASSEMBLY
LATCH FRONT
4)-2
4)-1
PLATE LATCH
Kmy03012EB
Disassembly/Reassembly
E
HARNESS ASSY-CON F (White)
Gap
HARNESS ASSY FRONT
Gap
COVER (Black)
Open and close the COVER ASSY FRONT to check if the harnesses routed through the
DUCT DRV PH are under no-load conditions.
1. Disconnect the connector (P/J272) of the HARNESS ASSY FRONT COVER (main unit side).
2. Release the HARNESS ASSY FRONT COVER from the DUCT DRV PH.
Make sure that the ground wire (green), HARNESS ASSY-CON F (white), and HARNESS
ASSY FRONT COVER (black), which are coming out of the COVER ASSY FRONT, are
routed as shown in figure-C.
3. Remove the screw (silver, self-tapping, 8 mm) that secures the terminal of the HARNESS ASSY
DRAWER EARTH to the COVER ASSY FRONT.
Revision C
HARNESS ASSY FRONT COVER
Figure-C
Ground Wire
(Green)
1)
2)
Kmy03089EA