AcuLaser C2800/C2800D/C3800/C3800D
D
4)-1
1. Remove the two screws (silver, self-tapping, 8 mm) that secure the DUCT SIDE L to the main unit.
2. Remove the DUCT SIDE L from the main unit.
3. Remove the screw (silver, self-tapping, 10 mm) that secures the LED ASSY to the main unit.
4. Release the two tabs on the LED ASSY and remove the LED ASSY from the main unit.
5. Disconnect the connector (P/J141) of the LED ASSY.
DISASSEMBLY/REASSEMBLY
LED ASSY
4)-1
LED ASSY
5)
4)-2
2)
1)
3)
1)